KAJIAN PENANGGULANGAN GENANGAN YANG TERINTEGRASI DI KAWASAN PILANG, PROBOLINGGO

Rahma Rismasari, Donny Harisuseno, Andre Primantyo Hendrawan

Abstract


ABSTRAK : Permasalahan genangan yang terjadi di daerah perkotaan mengekspresikan tidak terakomodirnya dengan baik kapasitas saluran drainase dan ketersediaan daerah resapan. Begitupun yang terjadi di Kawasan Pilang Probolinggo. Genangan menjadi permasalahan tahunan saat musim hujan tiba. Penelitian ini mengkaji penanggulangan genangan secara terintegrasi antara sistem baru yang diusulkan berupa sumur tampungan, dan kolam detensi dengan sistem drainase eksisting. Curah hujan rancangan dihitung dengan metode Gumbel dan Metode Log Person Tipe III untuk kemudian dibandingkan hasilnya, dan dipilih yang memenuhi persyaratan. Karena merupakan integrasi dari kerja 2 (dua) sistem drainase, sehingga perlu dianalisis potensi dalam mereduksi genangan dan potensi dalam menambah waktu tiba banjir. Dari hasil analisis diperoleh bahwa kejadian genangan historis mendekati perhitungan intensitas hujan kala ulang 2 tahun, sehingga sistem yang diusulkan didesain atas dasar debit rancangan kala ulang 5 tahun. Curah hujan rancangan diperoleh dengan metode Log Person Tipe III sebesar 125.304 mm. Dari hasil evaluasi kapasitas saluran terhadap debit rancangan, terdapat 12 saluran drainase eksisting yang kapasitasnya tidak memadai dalam menerima beban debit rancangan. Upaya penanggulangan secara terintegrasi dapat mereduksi genangan hingga 100%, dan dapat menunda waktu tiba banjirnya sebesar 83% pada 12 saluran yang diidentifikasikan terjadi genangan tersebut.

 

Kata kunci : genangan, waktu konsentrasi, sistem drainase terintegrasi, reduksi banjir, sumur tampungan

ABSTRACT : The problem of inundation that occurs in urban areas expresses not well accommodated drainage channel capacity and availability of catchment areasLikewise that happened in the area of Pilang Probolinggo. Inundation becomes an annual problem when the rainy season arrives. This study examines integrated inundation management between proposed new systems of storage wells, and detention pools with existing drainage systems. The design rainfall is calculated by Gumbel method and Log Person Type III Method, then compared the results, and selected eligible. Because it is an integration of the work of 2 (two) drainage systems, so it needs to be analyzed the potential in reducing the inundation and the potential in increasing the flood arrival time. From the analysis results obtained that the occurrence of historical inundation approach the calculation of rain intensity when re-2 years, so that the proposed system is designed on the basis of discharge design 5-year re-design. The design rainfall is obtained by Log Person Type III method of 125.304 mm. From the evaluation of channel capacity to discharge design, there are 12 existing drainage channels whose capacity is inadequate in accepting the design discharge load. Integrated mitigation efforts can reduce the inundation to 100%, and can delay the flooding time of 83% in the 12 channels identified in the inundation. 

Keywords : inundation, time of concentration, integrated drainage system, flood reduce, storage well


Full Text:

PDF

Refbacks

  • There are currently no refbacks.


Copyright (c) 2018 Jurnal Teknik Pengairan

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.